Congestive heart failure case study.pdf

History: This seventy-nine year old, 69” in height, 182lbs. Caucasian male complains of shortness of breath and fatigue. The patient’s medical history includes hypertension, congestive heart disease and hemorrhoids. The patient was recently hospitalized for a coronary artery bypass surgery. The patient’s medications include aspirin one a day, potassium chloride 100mg one a day, furosemide 40mg one a day (Diuretic), Synthroid 0.1mg one a day, Pacerone 200mg two a day, Zocar 20mg one a day, Coreg 25mg two a day (ß Blocker), Cozaar 50mg. His blood pressure today was 120/88. Patient referred to evaluate his hypertension and congestive heart failure therapy. BVA Results: Ideal Blood
Ideal Red
Cell Vol.
Ideal Plasma
Moderate
Clinical Findings: This patient has severe hypervolemia with a red cell volume at the lower limit of normal, and an extreme plasma volume excess. These results are consistent with congestive heart failure. The hypervolemia is caused exclusively by expansion of plasma volume. This patient’s hypertension is partially caused by hypervolemia. This patient most likely has extensive vasodilatation to accommodate this amount of hypervolemia. It is suggested that the patient’s Lasix be supplemented with Aldactone at 25mg 1-2 times a day. Aldactone, which blocks the aldosterone-sodium retention process, would allow water and sodium to be excreted but will preserve potassium. This patient’s apparent anemia (hematocrit of 30%) is an artifact and is completely due to his hypervolemia. If his blood volume were normalized his hematocrit would be in the 42-44 range. This quantification of total volume, red cell and plasma volume component will permit the monitoring of the patient’s response to Aldactone by serial hematocrits. When the patient’s blood pressure falls, it may be necessary to reduce the vasodilator therapy to avoid a hypotensive episode. Technical Analysis: Technical analysis consists of an evaluation of five separate blood volume collection points with mathematical evaluation of consistency. Technical evaluation is reported as acceptable or unacceptable. All five individual sampling points, tested in duplicate, were internally consistent with no significant deviations. The standard deviation was 2.69%. The slope was 0.00107 and is normal. Therefore, the results are technically acceptable.
Daxor Corporation Ƈ 350 Fifth Avenue, Suite 7120 Ƈ New York, NY 10118 Ƈ (888) 774-3268 Blood Volume Analysis Case Study Performed by Joseph Feldschuh, M.D., F.A.C.P., F.A.C.C. 3282 Reservoir Oval E. Bronx, NY 10467 History: This forty-nine year old male, 64” height and 169lbs. complains of shortness of breath. His past medical history includes hypertension and heart disease (diagnosed about five months ago). The patient’s medications include Lisinopril 40mg (ACE Inhibitor), Urinal-1, Ecotrin 325mg, Digoxin 0.2mg (Cardiac Glycoside), NTG-SL 0.4mg prn (Vasodialator), Coreg 6.25 mg B.I.D.(ȕ-blocker) and Lasix 80mg (Diuretic). The patient’s blood pressure today was 142/96. The patient was referred to evaluate his hypertension therapy. BVA Results: Ideal Blood
Ideal Red
Cell Vol.
Ideal Plasma
Moderate
Clinical Findings: This patient has a severe blood volume expansion with an extreme red cell volume excess. The patient also has a moderate plasma volume excess. The results are consistent with congestive heart failure. Diuretic therapy in this patient may provide some relief, but will result in an increase in hemoconcentration. The patient would benefit from a therapeutic phlebotomy which would reduce both his red cell and plasma volumes. The patient’s medications should be reduced just prior to the therapeutic phlebotomy. Therapeutic phlebotomy should be performed in increments to determine the patient’s therapeutic response. Reducing the patient’s blood volume toward normal can be expected to improve his blood pressure control with lower quantity of medication. Technical Analysis: Technical analysis consists of an evaluation of five separate blood volume collection points with mathematical evaluation of consistency. Technical evaluation is reported as acceptable or unacceptable. All five individual sampling points, tested in duplicate, were internally consistent with no significant deviations. The standard deviation was 2.14%. The slope was 0.00314 and is normal. Therefore, the results are technically acceptable.
Daxor Corporation Ƈ 350 Fifth Avenue, Suite 7120 Ƈ New York, NY 10118 Ƈ (888) 774-3268 Blood Volume Analysis Case Study Performed by Joseph Feldschuh, M.D., F.A.C.P., F.A.C.C. 3282 Reservoir Oval E. Bronx, NY 10467

Source: http://www.daxor.com/pdfs/chf-parts-1-and-2_feldschuh_daxor-case-study.pdf

Data linkage branch_projects1995-2012

Data Linkage Branch – Project Applications 1995 – 2010 Project Title Investigators Johnson Graeme, Fiona Stanley, Alison Plant Hospitalisation rates for women 20-60 years Breast cancer - patterns of care and outcomes Comorbidity in people with mental illness Key cancers - lung, colorectal, breast, melanoma Secondary prevention of Myocardial infarction SPLASH - Health behaviou

Microsoft word - form vmd-1105 lori's draft apr 27.doc

Wealthlink Financial Group Inc. – Fillable Form MEDICAL DECLARATION – Version V05 Instructions: a) Complete for any applicant age 60 to 85 who is applying for the Stable Chronic Condition Option. b) Complete for all applicants age 86 or over. c) Agent must fax to 1-866-285-5727 or mail to 21st Century within 3 business days of making sale. Agency Name ____________________________