Chemical Resistance of Polypropylene and Polyethylene
Generally speaking, the chemical resistance of polypropylene and polyethylene is considered superior to that of met-
als. They are unaffected by most inorganic acids, alkalis, and aqueous solutions which rapidly corrode metals, althoughsome concentrated acids and oxidizing agents can attack them, especially at elevated temperatures.
IMPORTANT NOTICE: This data refers to drainage systems usage only. For chemicals not listed, check with Orion. The information appearing here has been assembled from sources believed to be reliable, but is not guaranteed by Orion. Orion is not respon-
sible for its accuracy or reliabilty. In manufacturing its products, Orion uses raw materials manufactured by others, and Orion has no control over themethods used in installing its products or the conditions under which they are used. It does not make any representation concerning either the chem-ical resistance properties of its products or the toxicological effects of chemicals reacting with them. Nothing appearing here should be consideredas a recommendation for any use that would infringe patent rights or an endorsement for the use of any particular material or chemical or any classof materials or chemicals.
Aluminum, Potassium Sulfate (Potash Alum)
Acid Waste Piping Systems ORION FITTINGS, INC. 51 Chemical Resistance of Polypropylene and Polyethylene ORION FITTINGS, INC. Acid Waste Piping Systems Chemical Resistance of Polypropylene and Polyethylene Acid Waste Piping Systems ORION FITTINGS, INC. 53 Chemical Resistance of Polypropylene and Polyethylene ORION FITTINGS, INC. Acid Waste Piping Systems Chemical Resistance of Polypropylene and Polyethylene
Potassium Bichromate (see Potassium Dichromate)
Acid Waste Piping Systems ORION FITTINGS, INC. 55 Chemical Resistance of Polypropylene and Polyethylene ORION FITTINGS, INC. Acid Waste Piping Systems Chemical Resistance of PVDF
The information appearing here has been assembled from sources believed to be reliable, but is not guaranteed by Orion. Orion is not respon-
sible for its accuracy or reliabilty. In manufacturing its products, Orion uses raw materials manufactured by others, and Orion has no control over themethods used in installing its products or the conditions under which they are used. It does not make any representation concerning either the chem-ical resistance properties of its products or the toxicological effects of chemicals reacting with them. Nothing appearing here should be consideredas a recommendation for any use that would infringe patent rights or an endorsement for the use of any particular material or chemical or any classof materials or chemicals. apure substance unless otherwise indicated btemperatures in ºF have been rounded to ºC in 5 degree increments cNR indicates that KYNAR resin is not recommmended for use with the chemical at room temperature or at the temperature indicated
Ammonium PhosphateAqueous solution or solid
Ammonium ThiocyanateAqueous solution or solid 275
Aniline Hydrochloride Aqueous solution or solid
Benzenesulfonic Acid Aqueous solution or solid
Ammonium Bifluoride Aqueous solution or solid
Ammonium CarbonateAqueous solution or solid
Ammonium DichromateAqueous solution or solid
Ammonium Persulfate Aqueous solution or solid
Acid Waste Piping Systems ORION FITTINGS, INC. 57 Chemical Resistance of PVDF
Calcium Hypochlorite Aqueous solution or solid
ORION FITTINGS, INC. Acid Waste Piping Systems Chemical Resistance of PVDF
Disodium Phosphate Aqueous solution or solid
2-Ethoxyethyl Acetate Aqueous solution or liquid
Ethylene Chlorohydrin Aqueous solution or liquid
Acid Waste Piping Systems ORION FITTINGS, INC. 59 Chemical Resistance of PVDF
Methanesulfonic Acid Aqueous solution or liquid
Magnesium Chloride Aqueous solution or solid
ORION FITTINGS, INC. Acid Waste Piping Systems Chemical Resistance of PVDF
Potassium BicarbonateAqueous solution or solid
Potassium Carbonate Aqueous solution or solid
Potassium Chromate Aqueous solution or solid
Potassium FerricyanideAqueous solution or solid
Potassium FerrocyanideAqueous solution or solid 275
Potassium Hydroxide Greater than 50% in water
Potassium PermanganateAqueous solution or solid 250
Acid Waste Piping Systems ORION FITTINGS, INC. 61 Chemical Resistance of PVDF
Sodium Ferricyanide Aqueous solution or solid
Sodium Ferrocyanide Aqueous solution or solid
ORION FITTINGS, INC. Acid Waste Piping Systems
ROTARY 2 SL ENVIRONMENTAL HAZARDS DO NOT apply directly to water, or to areas where surface water is present, or to intertidal areas below the mean high water mark. DO NOT contaminate water when disposing of Specimen Label equipment washwaters or rinsate. This herbicide is phytotoxic at extremely low concentra-tions. Non-target plants may be adversely affected from drift. Alligare
Mirena® 20 micrograms/24 hours intrauterine delivery group A streptococcal sepsis) can occur fol owing IUS system (levonorgestrel) - Prescribing Information insertion. If pelvic infection suspected bacteriological (Refer to full Summary of Product Characteristics (SmPC) examinations & monitoring is recommended, even with discrete symptoms. Start appropriate antibiotics & remove